Anti-Human IgG (H&L) in sheep, rhodamine conjugate

Anti - Human IgG (H&L) in sheep, rhodamine conjugate - Polysciences
Anti - Human IgG (H&L) in sheep, rhodamine conjugate - Polysciences
Product Number:
23786

Size

Price

$263.94

Quantity

Bulk Request

Request a Bulk Quote 

Product Specifications

    No Technical Data Sheet

Safety Data Sheet (SDS)
Handling
    Exercise normal care
Storage
    Store at 4 degrees celsius
Hazards
    Harmless-use normal precautions
Hazard Code
    A2d
Related Documents

    No Related Documents

References

    No References

Product Description

Sheep Anti-Human IgG (H&L), Rhodamine Conjugate is a lyophilized fluorescent secondary antibody directed against the heavy and light chains of human immunoglobulin G (IgG). The rhodamine label enables fluorescence-based detection of human IgG and human IgG primary antibodies in immunodetection assays.

The conjugate is intended for fluorescence-based applications, including flow cytometry and tissue immunofluorescence. Instrument excitation and emission settings should be selected according to the spectral characteristics of the conjugated fluorophore.

Because immunoglobulin light chains are shared among antibody classes, secondary antibodies with heavy and light chain (H&L) reactivity can also recognize other immunoglobulin classes. This is an important consideration when selecting reagents for assays requiring IgG class specificity.

Key Properties

  • Product number: 23786
  • Product type: Fluorescent secondary antibody
  • Host species: Sheep
  • Target species: Human
  • Target immunoglobulin: IgG
  • Specificity: Heavy and light chains (H&L or H+L)
  • Conjugate: Rhodamine
  • Physical form: Lyophilized

Applications

Flow Cytometry

Rhodamine-conjugated sheep anti-human IgG provides a fluorescent detection reagent for flow cytometry assays involving human IgG or human IgG primary antibodies. The general starting dilution range for rhodamine conjugates is 1:50–1:200. Optimize the working antibody concentration according to sample composition, target abundance and instrument configuration.

Tissue Immunofluorescence

The conjugate can be used to visualize human immunoglobulins or detect human IgG primary antibodies in appropriately designed tissue immunofluorescence assays. The general starting dilution range for rhodamine conjugates is 1:200–1:1,000. When detecting human primary antibodies in human tissue, endogenous immunoglobulins can contribute to fluorescence independently of primary antibody binding. For compatible fluorescence microscopy preparations requiring aqueous mounting, Aqua-Poly/Mount provides a water-soluble mounting medium option.

Antibody Selection & Fluorescence Considerations

  • Select secondary antibodies according to the species and immunoglobulin specificity of the primary antibody
  • Match excitation wavelengths and emission detection bands to the spectral characteristics of the conjugated rhodamine fluorophore
  • Consider potential reactivity with other immunoglobulin classes through shared light chain epitopes, as well as cross-reactivity with immunoglobulins from other species
  • Account for spectral overlap in multicolor fluorescence assays and use appropriate compensation or spectral unmixing where applicable
  • Optimize the working antibody concentration through titration, using appropriate controls to assess specific fluorescence, autofluorescence and background labeling

Storage & Product Selection

  • Store the lyophilized conjugate at 4°C before reconstitution
  • Package size: 2 mg
  • Package catalog number: 23786-2
  • Cold-pack shipping required. Protect the fluorescent conjugate from unnecessary light exposure during handling and follow product-specific reconstitution and storage instructions.
  • Contact Polysciences for the current Safety Data Sheet (SDS), reconstitution instructions, fluorophore specifications and available lot-specific technical information
  • For larger quantities, request a bulk quote and specify Sheep Anti-Human IgG (H&L), Rhodamine Conjugate, catalog 23786

Why Choose Polysciences?

Research laboratories icon
Trusted by 6,000+ Researchers Worldwide
Peer reviewed studies icon
Cited in Thousands of Peer-Reviewed Studies
Made in USA icon
U.S. Manufacturing & Global Distribution
Global delivery icon
Reliable Delivery to 40+ Countries

FAQ

Click a question to expand.

1. What is rhodamine-conjugated sheep anti-human IgG used for?

Sheep Anti-Human IgG (H&L), Rhodamine Conjugate is a fluorescent secondary antibody for the detection of human IgG and human IgG primary antibodies. Relevant applications include flow cytometry and tissue immunofluorescence.

2. What does H&L mean in an anti-human IgG secondary antibody?

H&L refers to heavy and light chain reactivity. Antibodies with this specificity recognize epitopes associated with both the heavy and light chains of IgG. Reactivity with shared light chain epitopes can also result in recognition of other immunoglobulin classes.

3. What dilution should be used for the rhodamine-conjugated secondary antibody?

The general starting dilution ranges for rhodamine conjugates are 1:50–1:200 for flow cytometry and 1:200–1:1,000 for tissue immunofluorescence. Recommended dilutions for ELISA and blotting have not been determined in the general conjugate guidance. Determine the optimal working dilution for the specific assay following reconstitution, taking into account the stock antibody concentration and detection conditions.

4. What excitation and emission settings should be used for the rhodamine conjugate?

Excitation wavelengths and emission detection bands depend on the spectral properties of the specific rhodamine derivative. Contact Polysciences for fluorophore-specific information when selecting fluorescence microscope filters or flow cytometer detection channels.

5. Can sheep anti-human IgG (H&L) be used for immunofluorescence in human tissue?

Anti-human IgG secondary antibodies recognize endogenous human immunoglobulins as well as human IgG primary antibodies. This can complicate antigen-specific localization in indirect immunofluorescence assays. When detecting a human primary antibody in human tissue, consider alternative detection strategies if endogenous immunoglobulin labeling interferes with interpretation. Appropriate unstained and secondary-only controls help assess autofluorescence and labeling independent of the primary antibody.

6. Does the rhodamine-conjugated secondary antibody require reconstitution?

Yes. The antibody conjugate is lyophilized and requires reconstitution before use. Follow the product-specific reconstitution instructions and optimize the working antibody concentration for the intended application.

7. Where can I obtain technical specifications and safety information for this antibody?

Contact Polysciences for the current Safety Data Sheet (SDS), antibody formulation, reconstitution instructions, fluorophore characteristics and available lot-specific technical information for Sheep Anti-Human IgG (H&L), Rhodamine Conjugate, catalog 23786.

Anti - Human IgG (H&L) in sheep, rhodamine conjugate - Polysciences
Anti - Human IgG (H&L) in sheep, rhodamine conjugate - Polysciences
Product Specifications

    No Technical Data Sheet

Safety Data Sheet (SDS)
Handling
    Exercise normal care
Storage
    Store at 4 degrees celsius
Hazards
    Harmless-use normal precautions
Hazard Code
    A2d
Related Documents

    No Related Documents

References

    No References