ElectroPure™ Silver Stain Kit is a five-solution staining system for sensitive detection of proteins in polyacrylamide slab gels following electrophoresis. Maximum staining sensitivity is in the nanogram range, and the procedure can be used either before or after Coomassie® Blue staining.
The alkaline staining chemistry complexes silver ions with protein amino groups and with sulfur-containing cysteine and methionine residues. Subsequent development produces visible protein bands within the gel.
Key Properties
- Silver staining system for proteins in polyacrylamide slab gels
- Maximum staining sensitivity in the nanogram range
- Alkaline silver staining chemistry
- Can be used before or after Coomassie® Blue staining
- Five pre-formulated reagent solutions
- Store at room temperature
Kit contains:
- 28 mL Sodium Hydroxide
- 8 mL Formaldehyde
- 2 x 19 mL Ammonium Hydroxide
- 26 mL Silver Nitrate
- 28 mL Citric Acid
Applications
Protein Detection in Polyacrylamide Gels
ElectroPure™ Silver Stain Kit is used to visualize proteins separated in polyacrylamide slab gels. The method provides substantially greater staining sensitivity than routine visible protein staining methods when nanogram-range detection is required.
Post-Electrophoresis Protein Visualization
The staining procedure is performed after electrophoretic separation to visualize protein bands within the gel. The supplied protocol is designed for 1.0 mm mini-gels, with longer incubation times specified for thicker gels.
Silver Staining with Coomassie® Blue
Silver staining can be performed either before or after Coomassie® Blue staining. For conventional visible protein staining, see Coomassie® Blue R250, C.I. 42660.
Staining Considerations
- Use highly purified water of at least 18 megaohm/cm quality throughout washing and incubation steps
- Use thoroughly cleaned glassware to minimize contamination and background staining
- Maintain constant gentle agitation at approximately 40–60 rpm throughout the procedure
- The standard protocol is designed for 1.0 mm mini-gels
- For 1.5 mm gels, double the incubation times specified in the standard procedure
- Residual urea, glycerol, ampholines, SDS, Triton X-100, and reagent impurities can reduce sensitivity or increase background staining
Fixation, washing, development time, gel composition, and residual electrophoresis reagents can affect staining background and band intensity. Follow the ElectroPure™ Silver Stain Kit Technical Data Sheet for the complete procedure and troubleshooting guidance.
Application Tips
- Avoid direct contact with the gel during staining
- When manipulation is required, use powder-free gloves with plastic forceps or a disposable plastic pipette
- Keep the gel fully submerged and under constant gentle agitation during staining
- Prepare the Developing Solution immediately before use and use it within 2 hours
- Terminate development when the desired band intensity is reached
- If development proceeds too rapidly, 5–10% methanol may be added to the Developing Solution to reduce the development rate
- Collect silver-containing staining solution as silver waste and follow the neutralization and disposal instructions in the Technical Data Sheet
Handling & Storage
- Store the kit at room temperature
- Use appropriate laboratory ventilation or a chemical hood
- Wear suitable protective gloves and chemical splash goggles during handling
- Avoid contact of kit reagents with skin and eyes
- Do not allow prepared ammoniacal silver Staining Solution to remain standing after use; follow the silver-waste procedure in the Technical Data Sheet
Why Choose Polysciences?
Trusted by 6,000+ Researchers Worldwide
Cited in Thousands of Peer-Reviewed Studies
U.S. Manufacturing & Global Distribution
Reliable Delivery to 40+ Countries
FAQ
Click a question to expand.
1. What is the ElectroPure™ Silver Stain Kit used for?
ElectroPure™ Silver Stain Kit is used for sensitive visualization of proteins separated in polyacrylamide slab gels following electrophoresis.
2. How sensitive is the ElectroPure™ Silver Stain Kit?
Maximum staining sensitivity is in the nanogram range. Staining quality depends on appropriate fixation, washing, reagent preparation, development time, and control of interfering substances in the gel.
3. Can silver staining be performed before or after Coomassie® Blue staining?
Yes. The ElectroPure™ procedure can be used before or after Coomassie® Blue staining. For conventional protein staining, see Coomassie® Blue R250.
4. How does the ElectroPure™ silver staining method detect proteins?
Under alkaline staining conditions, silver ions complex with protein amino groups and with sulfur-containing cysteine and methionine residues. The subsequent development step produces visible protein bands.
5. What reagents are included in the kit?
The kit contains sodium hydroxide, formaldehyde, ammonium hydroxide, silver nitrate, and citric acid solutions.
6. What gel thickness is the standard protocol designed for?
The standard procedure is designed for 1.0 mm mini-gels. For 1.5 mm gels, the Technical Data Sheet specifies doubling the incubation times.
7. Can the ElectroPure™ method also stain DNA or RNA?
The supplied procedure is specifically directed toward protein staining. The Technical Data Sheet notes that DNA and RNA can also be detected by silver staining, but it does not provide a separate nucleic acid staining protocol.
8. What can cause high background during silver staining?
High background can result from over-development or residual chemicals in the gel. Urea, glycerol, ampholines, SDS, Triton X-100, and reagent impurities can interfere with the staining reaction and may require additional fixation or washing.
9. How should the kit be stored?
Store the ElectroPure™ Silver Stain Kit at room temperature.
10. Where can I find the complete staining protocol?
The complete reagent preparation, staining procedure, troubleshooting guidance, and silver-waste instructions are available in the ElectroPure™ Silver Stain Kit Technical Data Sheet.
11. Can I request multiple kits or a larger order?
Yes. For larger orders, use the bulk-quote option.
Safety & Documentation
The five kit reagents have different handling requirements. Review the Technical Data Sheet #293 before beginning the staining procedure and consult the applicable Safety Data Sheet for each component: Sodium Hydroxide, Ammonium Hydroxide, Silver Nitrate, Citric Acid, and Formaldehyde.