Biodegradable Polymers / PLGA

PLGA Polymer Supplier for Drug Delivery and Medical Device Development

Polysciences supplies research-use poly(lactide-co-glycolide) (PLGA) for teams developing controlled-release formulations and bioresorbable medical device materials. Our U.S.-based technical team works with customers who are selecting polymers for new development programs as well as those evaluating an alternative material source.


What sourcing teams need from a PLGA partner

Material specifications

Polymers with similar solution viscosities can have different molar-mass distributions. Depending on the application, these differences may influence processing behavior. Understanding which molecular attributes are critical to your process helps narrow the field of candidate materials.

Comparable analytical data

The method behind a reported value can be just as important as the value itself. When comparing materials from different suppliers, review the analytical conditions alongside the reported specification and its acceptance criteria.

Supply continuity

Changing a polymer source can become more complicated as development progresses and material behavior becomes better characterized. Discussing projected demand and lot-level requirements early gives both the supplier and the development team a clearer understanding of future sourcing needs.

Flexibility beyond catalog grades

A standard PLGA grade may offer the viscosity you need while falling short of a particular chain-end requirement. In situations like these, a conversation with a polymer chemist can help determine whether a custom specification is worth pursuing.


Available PLGA grades for research and formulation development

Our 50:50 PLGA portfolio includes two acid-terminated polymers alongside several other viscosity options. Researchers interested in a higher lactide content can also explore our 75:25 grades. If IV is an important part of your selection criteria, our guide to interpreting PLGA inherent viscosity explains how measurement conditions influence the comparison of polymer viscosity data.

Scroll horizontally to view all product details.

Selected Polysciences PLGA research grades
Lactide:Glycolide Ratio Nominal IV (dL/g) End Group Product Number Product Link
50:50 0.2 Acid-terminated 26269 View PLGA 50:50, IV 0.2
50:50 0.4 Acid-terminated 26270 View PLGA 50:50, IV 0.4
50:50 0.6 Not specified 23986 View PLGA 50:50, IV 0.6
50:50 1.0 Not specified 23987 View PLGA 50:50, IV 1.0
75:25 0.65 Not specified 25107 View PLGA 75:25, IV 0.65

IV values are nominal. Consult the individual product specifications for measurement methods and test conditions. Where end-group chemistry is not listed, contact our team for additional information.

Looking for additional PLGA grades?

Our broader portfolio includes additional 75:25 and 85:15 compositions, with select acid-terminated and ester-terminated powder grades available for research.

Explore All PLGA Grades

Choosing PLGA for drug delivery and medical device development

A polymer's properties at the point of purchase represent only the beginning of its material history. As discussed in our article on PLGA for bioresorbable medical device applications, fabrication can influence the properties of the finished material. Understanding these changes is particularly valuable when interpreting drug release or device degradation data.

Drug delivery and controlled-release research

During PLGA microsphere fabrication, solvent extraction influences the hardening of the polymer-rich phase. Changes in this process can affect particle morphology and the amount of drug retained within the polymer matrix.

For scientists developing long-acting delivery systems, it is useful to interpret drug release data in the context of particle preparation. This helps distinguish the contribution of the starting polymer from effects introduced during formulation.

Bioresorbable medical device development

Loss of mechanical integrity can precede substantial gravimetric mass loss in hydrolytically degrading PLGA. Article geometry is also relevant, since longer diffusion pathways can favor the accumulation of acidic degradation products within the material.

When screening polymers for an investigational implant, consider how long the material must retain its intended function. Mechanical retention data may be more informative than mass-loss measurements alone.


When standard PLGA grades don't meet your needs

Sometimes the polymer your application requires falls outside the specifications of commercially available grades. Our custom synthesis capabilities provide an opportunity to explore those requirements directly with our technical team.

Perhaps you already know the IV range you need and want to explore a different end-group chemistry. Or you may be investigating an unexpected experimental result and suspect that a change in polymer chemistry could improve performance.

Either is a good starting point for a conversation. Tell us what you're working on, even if your material specification is still taking shape. Together, we can discuss what might be technically feasible and scope the work accordingly.


A U.S.-based technical partner for PLGA development and sourcing

The questions scientists ask about a polymer often change as their development programs mature. Polysciences brings decades of chemical experience to these conversations. Our contract manufacturing capabilities complement our research and synthesis expertise, allowing us to discuss material needs beyond initial laboratory evaluation.

Processing-related changes can become particularly apparent during scale-up. In our article on troubleshooting PLGA device data, we examine why a change in fabrication conditions may produce different experimental results, even when the incoming polymer specification remains unchanged.

Research and development

Characterizing a polymer before and after fabrication can help identify processing-related molecular-weight loss. Our R&D team can discuss material selection in the context of the experimental changes you're observing.

Custom synthesis

Chain-end chemistry can be considered separately from the nominal lactide-to-glycolide ratio. If a particular molecular attribute is important to your application, our synthesis team can discuss the feasibility of targeting it.

Scale-up and manufacturing

Increasing process volume can change the thermal history of a polymer, particularly when residence times or drying conditions differ. Share your process constraints and anticipated quantities with us to explore potential manufacturing arrangements.


Quality systems and PLGA supplier documentation

As material evaluation progresses, access to analytical documentation becomes increasingly important. Polysciences maintains an ISO 13485:2016-certified quality management system and FDA establishment registrations. Information about the scope of these company and facility credentials is available on our quality systems and certifications page.

Our catalog PLGA grades are supplied for research use only. We encourage customers with additional qualification or manufacturing requirements to discuss their project directly with our team.

Documentation and material requirements to discuss

  • Product specifications and safety data sheets
  • Lot-specific analytical documentation
  • Viscosity measurement methods
  • Composition and chain-end characterization
  • Molar-mass characterization
  • Residual monomer and moisture requirements
  • Material traceability
  • Change-control requirements

Documentation availability varies by grade. If your organization has a defined material qualification process, share its requirements with us so we can review the information available for your evaluation.


Tell us what your PLGA needs to do

You know your application better than anyone. Sharing what you've learned about your material so far gives our technical team a useful starting point for evaluating your requirements.

Technical consultation

Start a conversation with our team

Describe your application

What function does the polymer need to serve? If you're working through an unexpected experimental result, tell us where it occurs in your development process.

Share your starting specification

Send us any polymer specifications or analytical methods you're already working with. If you're considering a second source, the specification for your existing material is especially useful.

Define your project requirements

Let us know the quantities you're anticipating and when you'll need the material. Include any documentation requirements relevant to the current stage of your program.


Technical resources for PLGA evaluation and development

Explore additional resources covering supplier selection, polymer characterization, and material development considerations.

Evaluating a PLGA supplier

Explore the material specifications, quality considerations, and sourcing questions that can inform supplier evaluation.

What to Look for in a PLGA Supplier

Understanding PLGA viscosity measurements

Learn why viscosity definitions and measurement conditions matter when comparing polymer grades and supplier specifications.

Interpreting PLGA Inherent Viscosity

Troubleshooting material variability

Examine how processing conditions and material characteristics can influence the interpretation of PLGA device development data.

Troubleshooting PLGA Device Data

Frequently asked questions about PLGA sourcing

Click a question to expand.

Yes. Our technical team welcomes inquiries about PLGA specifications outside our standard portfolio. We assess custom development requests individually to determine technical feasibility and project scope. You can contact us at any stage of your material development work.

Yes. We recommend beginning with the specification and analytical methods for your existing polymer. From there, we can discuss which catalog grades or custom material options may warrant further investigation. Comparative testing within your own process is an important part of qualifying an alternative source.

No. Inherent viscosity is determined at a finite polymer concentration, whereas intrinsic viscosity represents the limiting value as concentration approaches zero. Both are commonly expressed in dL/g. For a meaningful comparison, check which viscosity definition was used and review the associated measurement conditions.

Start with the documentation listed on the individual product page. If you need lot-specific information or additional analytical data, send our team the product number along with your requirements. We can review which documents are available for that material.

The PLGA grades featured on this page are polymer starting materials for research and development. If your project calls for engineered particles, contact our technical team to discuss the specific requirements and potential feasibility of that work.